1
ASSEMBLY AND USER INSTRUCTIONS
FOR
OUTDOOR BUILT-IN GAS FIRE BURNER KIT
Your new SR2201BI/I2+, SRR2201BI/I2+ & 4001BIS/I2+, SR4001BIR/I2+ BUILT-IN GAS FIRE
BURNER KIT is made from the highest quality materials, and produced under strict manufacturing
controls.
Please read the Instructions for assembly before commencing, and follow the instructions for use
carefully. We congratulate you on your decision to buy this outdoor built-in gas fire burner kit and wish
you great fun when warming with it.
PLEASE READ THESE SAFETY INSTRUCTIONS
IN FULL BEFORE COMMENCING ASSEMBLY.
Important Safety instructions
The built-in gas fire burner kit is safe and easy to use. The following rules must be followed.
1. Ensure that the unit has been assembled correctly according to the instructions.
2. Never loosen, or allow the gas connection to become loose. Should this happen,
immediately ensure that the gas is turned off at the cylinder or main shut off valve of city
network gas, and then re-check the security of the connection.
3. The appliance shall be kept away from flammable materials.
4. Read the Users instruction, Sections, and instructions written on the built-in gas fire burner
kit, refer to them whenever necessary.
5. Never leave the built-in gas fire burner kit unattended while using.
6. In the event of a gas leak, the appliance shall not be used or if alight, turn off gas supply at
the LPG cylinder or the nearest main shut off valve of city network gas. And the appliance
shall be investigated and rectified before it is used again.
7. Keep children well clear while built-in gas fire burner kit is in use and after use until it has
cooled.
8. Keep warming area, 1m away from the appliance, clear of combustible materials and/or
liquids.
9. Never obstruct free flow of air to the built-in gas fire burner kit, or alter/adapt the built-in gas
fire burner kit to suit any other situation.
10. SR/R2201BI & SR4001BIS/R: A hose conforming to the national standard must be
connected at one end to the LPG regulator and at the other to the fire pit nipple using hose
clips. The hose length is 1m.
SR/R2 & SR4001BIS/R/I2+:
A hose conforming to the national standard must be
connected at one end to the main shut off valve of city network gas and at the other to the
fire pit inlet with a national standard NG connector. For the hose exposed, please be sure to
use (a) rubber/PVC layer(s) to cover on it to prevent people from stumbling. The proper
rubber/PVC layers are available from the same dealer or qualified installer.
The material of any description should not be thrown on to the fuel bed.
The appliance should not be used in bathroom or bedrooms.
The appliance is only intended to be used as secondary heating.