16
17
ZERO DISPLAY STATE:
> The cold water button turns off and, after 10 s, the natural
intermittent water button with intermittent filter light comes on.
USER ACTIVITY:
> Press the natural water button (which becomes steady).
ZERO DISPLAY STATE:
> The natural water button goes out;
> The intermittent cold water and intermittent filter indicator comes on.
USER ACTIVITY:
> Press the cold water button (which becomes fixed).
ZERO DISPLAY STATE:
> The cold water button goes out;
> The intermittent cold water button comes on again;
> The filter light stays on intermittently .
USER ACTIVITY:
> Press the cold water button (which becomes fixed;
NOTE:
To fill the internal tank, the dispensing buttons remain off.
ZERO DISPLAY STATE:
> When the internal tank is full, the filter light goes out;
> The dispensing buttons and the temperature regulator come on (set
= 8°C).
USER ACTIVITY:
> Remove the container over the drip tray and the machine is ready
for use;
> Fill the external water tank.
ATTENTION:
In the event of power outages or depletion of the external
tank water during the first activation phase at the end user, the
machine restarts upon recovery/filling:
From the beginning, if the natural water bottle is not calibrated.
From filling of the internal tank, if the natural water bottle has been
calibrated.
In the event of problems, simply switch the machine off and on again
(or press the natural H
2
O key) to reset the timeout and to resume
from the point of interruption.
L
M
N
O
TANK LEVEL DEPLETION
If the user uses the water until the external tank runs out of water, the capacitive sensor detects the reaching
of the minimum level and the drop light on the display lights up.
By partially refilling the external tank the crossed drop light goes off and the dispensing buttons and
temperature adjustment buttons are turned back on until stand-by. The crossed drop light also comes on
when the external tank is removed (for example for cleaning or filling).
If the external tank runs out before filling of the internal tank, in addition to the external tank level light, an
intermittent beep is activated immediately.
Simply fill the external tank.
NOTE COLD WATER DISPENSING:
During filling of the internal tank, the extraction of water is inhibited, the cold water and natural water buttons
are off. If the water in the external tank ends (with the buttons turning off and the tank level light turning on)
during the internal tank filling operations, the phase will be completed when the water in the external tank
is refilled.
GENERAL NOTE WATER DISPENSING:
The user can take cold water at any time, even if the set temperature is not reached.
HOW TO CALIBRATE THE BOTTLE (in the period following the first use):
> Keep the cold water or ambient water button pressed for 5 seconds
(in the meantime the machine will
start dispensing at the first touch without waiting for 5 seconds)
; during the 5 seconds DO NOT remove
your finger from the button.
> The dispensing time adjustment procedure has been activated
> The button starts flashing;
> Take your finger off the button;
> Press the button again (simply place your finger on it for a minimum of 0.3 s) to stop the water;
> At this point the new automatic open/close time is recorded.
At the end of the cold water bottle calibration the machine always fills the internal tank. Calibration of the
cold water bottle is only possible when the internal tank is full; the function is therefore inhibited after the
extraction of cold water.
The maximum cold water setting programming time is 23 s, while for the ambient temperature it is 85 s.
HOW TO SET
THE TEMPERATURE
HOW TO DISPENSE
AMBIENT WATER
HOW TO DISPENSE
COLD WATER
HOW TO USE THE HAPPY FRIZZ ZERO
Summary of Contents for ZERO
Page 20: ...38 39...