17
8
6-2-9 Trouble shooting (Malfunction of needle bar change)
Trouble Factor Cause of trouble and measure
Page
Head does not
Mechanical
1. Check lint or cloth is seized between
Lower Moving rail and Bearing.
move 1-1 Remove seized lint or cloth.
(E-021)
2. Check lint or waste is seized in gap of Moving Cam.
(E-022)
2-1 Remove seized lint or waste.
3. Effect by breakage of parts.
3-1 Repair broken place.
Operator 1. Check Stopper of Moving Head is removed.
1-1 Remove Stopper.
Uncontrollable
Mechanical
1. No problem in sensor circuit board ?
Move
1-1 Clean dust attached to sensor.
(E-024)
1-2 Replace sensor circuit board.
4-2-3
(E-025) 2. Trouble in potentiometer.
2-1 Replace
4-2-4
3. Needle number is not exactly recognized.
3-1 Recognize needle number with maintenance mode.
3-4-2
4. Breakage of Pulse Motor .
4-1 Replace Pulse Motor.
( ) ---Reference instruction book
Summary of Contents for HCS2-1201-30
Page 1: ...Maintenance Manual for Embroidery Machine HCS2 1201 30 Version 2 3 HappyJapan Inc...
Page 154: ...153 5 1 1 Electrical connection diagram except for Rev A...
Page 155: ...154 5 1 1 Electrical connection diagram except for Rev A...
Page 156: ...155 5 1 2 List of electrical connection diagrams except for Rev A...
Page 157: ...156 5 1 3 Electrical connection diagram for Rev A...
Page 158: ...157 5 1 3 Electrical connection diagram for Rev A...
Page 159: ...158 5 1 4 List of electrical connection diagrams for Rev A...
Page 160: ...159 5 2 1 Connection of inverter 100V Inverter set...
Page 161: ...160 5 2 2 Connection of inverter 200V Inverter set...
Page 165: ...160c HCD8116 TP switch board ass y 6 5 265 2 1 6 7 257...