181a
6-3-1
Startup error and measure (Main program Ver.*1.37~)
Error message will be displayed if error occurs during machine startup.
After confirming contents, press button [OK] on control box to release error, then restore in accordance with
measure in this list.
Message
Error
Measure
Exchanged
control box or
CONT board does
not match for the
installed data of
[Machine setting].
When only control box has been
exchanged, open the menu of [4-5-4-5
Setup — Machine setting] and just close
without any amendment.
When CONT board has been exchanged,
follow the procedure of [4-5-4-7 Machine
Setting Navigation after exchanging CONT
board].
Installed frame
drive data in the
machine does not
match.
Check setting contents of [Machine setting]
by referring [4-5-4-5 Setup—Machine
setting], then follow the procedure
[4-4-3Machine program update].
Summary of Contents for HCS2-1201-30
Page 1: ...Maintenance Manual for Embroidery Machine HCS2 1201 30 Version 2 3 HappyJapan Inc...
Page 154: ...153 5 1 1 Electrical connection diagram except for Rev A...
Page 155: ...154 5 1 1 Electrical connection diagram except for Rev A...
Page 156: ...155 5 1 2 List of electrical connection diagrams except for Rev A...
Page 157: ...156 5 1 3 Electrical connection diagram for Rev A...
Page 158: ...157 5 1 3 Electrical connection diagram for Rev A...
Page 159: ...158 5 1 4 List of electrical connection diagrams for Rev A...
Page 160: ...159 5 2 1 Connection of inverter 100V Inverter set...
Page 161: ...160 5 2 2 Connection of inverter 200V Inverter set...
Page 165: ...160c HCD8116 TP switch board ass y 6 5 265 2 1 6 7 257...