15
CARE AND MAINTENANCE
At least twice each year, tighten all screws on the fan . Clean the motor housing with only a soft brush
or lint-free cloth to avoid scratching the finish. Clean the blades with a lint-free cloth.
Bulb Replacement: Use 75-watt max . halogen bulb or LED equivalent . CFL and incandescent bulbs
are not recommended for this item .
Battery Replacement for Remote: Use A23 12-volt battery .
Important:
Shut off the main power supply before you begin any maintenance tasks . Do not use
water or a damp cloth to clean the ceiling fan .
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
The fan does not
move .
1 . The power is off or the fuse is
blown .
2 . There is a faulty wire connection .
3 . The plugs are not connected
properly .
4 . The reverse switch is not
completely engaged .
1 . Turn the power on or check the
fuse .
2 . Turn the power off . Loosen the
canopy and check all connections .
3 . Check that the connectors from
the light kit and fan are connected
properly .
4 . Push the seasonal slide switch
completely to the left or right .
There is excessive
wobbling .
1 . The blades and/or blade arms are
loose .
2 . The blades are unbalanced .
3 . The fan mounting is not secure .
1 . Check and tighten all screws that
hold the fan blades to the blade
arms and the blade arms to the
motor .
2 . Switch one blade with a blade from
the opposite side . Or balance the
fan using the blade balancing kit
(P) .
3 . Turn off the power . Loosen the
motor housing and verify the upper
mounting bracket is secure to the
electrical outlet box . The bracket
must be flush without movement
against the outlet box .
The fan operates
correctly, but the
lights are not
working .
1 . The bulbs are not installed
correctly .
2 . The light kit wire plugs are not
connected properly .
3 . There is a faulty wire connection .
1 . Re-install the bulb(s) .
2 . Ensure the single-pin connectors in
the light kit are connected properly .
3 . Turn the power off and check all
connections at the ceiling outlet
box .