17
Lowes.com/harborbreeze
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
There is excessive
wobbling.
1. The blades and/or blade are
loose.
2. The blades are unbalanced.
3. The fan mounting is not
secure.
4. The fan is too close to the
vaulted ceiling.
5. The set screw on the motor
housing yoke is loose.
1. Check and tighten all screws that
hold the fan blades to the blade
arms and the blade arms to the
motor.
2. Switch one blade with a blade from
the opposite side. Or balance the
fan using the blade balance kit (K).
3. Turn off the power. Loosen the
canopy and verify that the mounting
bracket is secure to the electrical
outlet box. The bracket must be
flush without movement against the
outlet box. Verify the outlet box is
secure.
4. Use a longer downrod (sold
separately) or move the fan to
another location.
5. Tighten the set screw to the yoke
until secure.