background image

16

FCC WARNING

This device (including remote control and LED module) complies with Part 15 of the FCC Rules. 

Operation is subject to the following two conditions:

(1) This device may not cause harmful interference, and (2) this device must accept any interference

received, including interference that may cause undesired operation. Please note that changes or

modifications not expressly approved by the party responsible for compliance could void the user's

authority to operate the equipment.

Note: Both the remote control and LED module have been tested and found to comply with the limits

for Class B digital device,pursuant to part 15 of the FCC Rules. These limits are designed to provide

reasonable protectionagainst harmful interference in a residential installation.

The remote control generates, uses and can radiate radio frequency energy and, if not installed and

used in accordance with the instructions, may cause harmful interference to radio or television

reception, which can be determined by turning the equipment off and on, the user is encouraged to

try to correct the interference by one or more of the following measures:

- Reorient or relocate the receiving antenna.

- Increase the separation between the equipment and the receiver.

- Connect the equipment into an outlet on a circuit different from that to which the receiver is

connected.

Consult the dealer or an experienced radio/TV technician for help.

L G Sourcing, Inc.

1000 Lowe’s Blvd.

Mooresville, NC 28117

1-800-643-0067

Summary of Contents for HTD20005

Page 1: ...ered trademark of LF LLC All Rights Reserved 1 Espa ol p 18 Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 643 0067 8 a m 8 p m EST Mo...

Page 2: ...ons Wiring Instructions Final Installation Instructions Operation Instructions Care and Maintenance Troubleshooting Limited Lifetime Warranty FCC Warning Safety Information 4 Package Contents Hardware...

Page 3: ...te Unit 3 PART DESCRIPTION QUANTITY 1 H Trim Ring Preassembled on Motor Assembly B 4 I Mounting Screw Preassembled on Motor Assembly B 3 J Mounting Plate Screw Preassembled on Motor Assembly B 3 K Swi...

Page 4: ...he lighting fixture must be positioned so there is at least 1 64 ft between the bulb and any illuminated surface For supply connections if the conductor of a fan is identified as a grounded conductor...

Page 5: ...n cause severe internal burns and can lead to death in as little as 2 hours Always completely secure the battery compartment If the battery compartment does not close securely stop using the product r...

Page 6: ...rn off circuit breakers and wall switch to the fan supply line leads installation may result in serious injury or death or T Turn Off Power Source 3 Check existing outlet box not included to ensure it...

Page 7: ...ting screws I on the round holes keep for later use And loosen the other two screws I 5 Hang the motor assembly B onto the hook from the ceiling plate A This will allow for hands free wiring INITIAL I...

Page 8: ...it must be grounded for safe operation WARNING If house wires are different colors than referred to in the following steps stop immediately A professional electrician is recommended to determine prope...

Page 9: ...wise until the screw heads engage the keyhole slots fully Make sure not to break any wire connections 2 Re install two mounting screws I to the round holes securely tighten four 4 mounting screws I 9...

Page 10: ...L INSTALLATION INSTRUCTIONS B J 6 Insert the 9 pin connector from the motor assembly B through the center hole in the switch housing C Attach the switch housing C to the mounting plate on the motor as...

Page 11: ...by twisting in a clockwise direction Do not over tighten FINAL INSTALLATION INSTRUCTIONS 7 C E K 8 C F OPERATION INSTRUCTIONS 1 When the season changes you may want to change the direction in which t...

Page 12: ...tiple fans installed within a close proximity and want to control all fans using a same remote transmitter NOTE Each fan requires its own receiver NOTE sure battery is not flat After you have replaced...

Page 13: ...with dimmer function b on ON without dimmer function Note Factory set is on DIM position If the light is not dimmable slide it to ON position otherwise it may cause the light to flicker CARE AND MAIN...

Page 14: ...Blade is loose 5 Check that all blades are screwed firmly into blade holders Fan sounds noisy Fan wobbles TROUBLESHOOTING PROBABLE CAUSE CORRECTIVE ACTION PROBLEM 6 Blade holders are loose 6 Check to...

Page 15: ...hanges in brass finish rusting pitting tarnishing corroding or peeling Brass finish fans maintain their beauty when protected from varying weather conditions The duration of any implied warranty which...

Page 16: ...FCC Rules These limits are designed to provide reasonable protectionagainst harmful interference in a residential installation The remote control generates uses and can radiate radio frequency energy...

Page 17: ...0 643 0067 8 a m 8 p m EST Monday Sunday A Ceiling Plate A102 0365036 C Switch Housing A121 0470213 D Blade A141 0641030 E Light Kit A187 0516036 F Bowl A182 0502036 G Remote Unit A137 0540032 AA Blad...

Page 18: ......

Reviews: