background image

SKU 65003 

For technical questions, please call 1-800-444-3353. 

Page 12

part

Description

Qty.

1

Blower Tube

1

2

Switch Assembly

4

3

Switch

1

4

Screw (ST3x18)

2

5

Trigger

1

6

Left Housing

1

7

Handle Jacket

1

8

Spring Assembly

6

9

Bracket

1

10

Internal Wire

1

11

Pin

4

12

Battery Pack

1

part

Description

Qty.

13

Motor Assembly

6

14

Motor

1

15

Fixed Cover

1

16

Washer (Ф4)

2

17

Screw (M4x8)

2

18

Fan

1

19

Right Housing

1

20

Screw (ST4.2x15)

13

21

Spring

1

22

Inlet

1

23

Charger

1

24

Charger Stand

1

paRtS LiSt anD aSSEmBLY DiagRam

pLEaSE REaD tHE FOLLOWing CaREFuLLY

THE MANUfACTURER AND/OR DISTRIbUTOR HAS PROVIDED THE PARTS LIST AND ASSEMbLy DIAgRAM IN 

THIS MANUAL AS A REfERENCE TOOL ONLy.  NEITHER THE MANUfACTURER OR DISTRIbUTOR MAKES ANy 

REPRESENTATION OR WARRANTy Of ANy KIND TO THE bUyER THAT HE OR SHE IS qUALIfIED TO MAKE ANy REPAIRS 

TO THE PRODUCT, OR THAT HE OR SHE IS qUALIfIED TO REPLACE ANy PARTS Of THE PRODUCT.  IN fACT, THE 

MANUfACTURER AND/OR DISTRIbUTOR ExPRESSLy STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD 

bE UNDERTAKEN by CERTIfIED AND LICENSED TECHNICIANS, AND NOT by THE bUyER.  THE bUyER ASSUMES ALL 

RISK AND LIAbILITy ARISINg OUT Of HIS OR HER REPAIRS TO THE ORIgINAL PRODUCT OR REPLACEMENT PARTS 

THERETO, OR ARISINg OUT Of HIS OR HER INSTALLATION Of REPLACEMENT PARTS THERETO.

Summary of Contents for 65003

Page 1: ...opyright 2008 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor...

Page 2: ...afety alert symbol indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the...

Page 3: ...s hard hat or hearing protection used for appropri ate conditions will reduce personal injuries Prevent unintentional starting d Ensure the switch is in the off po sition before connecting to power so...

Page 4: ...battery pack Use power tools only with specifi b cally designated battery packs Use of any other battery packs may create a risk of injury and fire When battery pack is not in use c keep it away from...

Page 5: ...15 tures below 0 C or above 40 C 32 F 104 F The batteries are Ni CD nickel cad 16 mium Follow all local regulations in regards to disposing of Ni CD batter ies This product is not a toy Keep it out 1...

Page 6: ...g vibrating tools regu 1 larly or for an extended period should first be examined by a doctor and then have regular medical check ups to ensure medical problems are not being caused or worsened from u...

Page 7: ...ing provides a low resistance path to carry electricity away from the user reducing the risk of electric shock See 3 Prong Plug and Outlet The grounding prong in the plug is 2 connected through the gr...

Page 8: ...u are using one extension cord 5 for more than one tool add the nameplate amperes and use the sum to determine the required minimum cord size See Table A If you are using an extension cord 6 outdoors...

Page 9: ...bling or making any adjustments to the tool Note For additional information regarding the parts listed in the following pages refer to the Assembly Diagram near the end of this manual Installing Remov...

Page 10: ...slide Tube off housing Operating Instructions Read the entire Important Safety Information section at the beginning of this manual including all text under subheadings therein before set up or use of...

Page 11: ...nt or binding of moving parts cracked or broken parts and any other condition that may affect its safe operation After Use 2 clean external surfaces of the tool with clean cloth Do not use harsh solve...

Page 12: ...EFULLY The manufacturer and or distributor has provided the parts list and assembly diagram in this manual as a reference tool only Neither the manufacturer or distributor makes any representation or...