Page 12
For technical questions, please call 1-888-866-5797.
Item 57042
RETURNS NOT ACCEPTED & WARRANTY VOID
if Sprayer is not properly cleaned immediately after every use.
Clean Sprayer immediately to prevent permanent damage.
S
AFETY
O
PERA
TION
M
AINTENANCE
S
ETUP
TO PREVENT SERIOUS INJURY:
Do not spray flammable or combustible liquids in a confined area. Spray area must be well ventilated.
Do not smoke while spraying or spray where sparks or flame is present. Keep pump assembly in a
well ventilated area at least 20 feet (6.1 m) from the spray area. Do not spray the pump assembly.
Do not use bleach or halogenated hydrocarbon solvents (DCM, 1,1,1– trichloroethane, methyl
bromine, carbon tetrachloride, and ethyl iodide). Long term exposure to many chlorinated
hydrocarbons through inhalation can result in liver and kidney toxicity. Exposure of unprotected
skin to the solvents used can cause defatting of the skin resulting in dermatitis. Methylene chloride
and vinyl chloride have also been shown to be human carcinogens. Some of these solvents are
flammable. Welding operations near the these materials can create phosgene, a highly toxic gas.
Wear ANSI-approved safety goggles, NIOSH-approved respirator, and heavy-duty work gloves during use.
Priming
WARNING! TO PREVENT SERIOUS INJURY: Only water-based materials or materials with a
minimum flash point of 38°C (100°F) should be used for spraying and cleaning.
Only use water
or mineral spirits for priming and cleaning. Only use water-based or oil-based paint for spraying.
Prime with Solvent
WARNING! To prevent high pressure
solvent or paint splatter, remove Nozzle
Guard and Spray Tip according to
Spray
Tip and Nozzle Guard on page 19.
1. Depressurize Sprayer according to
Depressurize Sprayer on page 11.
2. Lock Trigger.
3.
Cover floor under Sprayer and
containers with drop cloth.
4. Designate two 1 gallon or larger containers,
one for solvent and one for waste. If using
mineral spirits, use metal containers.
5. Separate Priming Hose from Suction Hose.
a. Place Suction Hose on bottom
of solvent container.
b. Place Priming Hose on bottom
of waste container.
Suction
Hose
Priming
Hose
Solvent
Waste
6. Fill solvent container with enough solvent
to cover Suction Filter by 1".
• Water for water-based paint.
• Mineral spirits for oil-based paint.
7.
Prime Pump:
a. Turn Pressure Knob to
PRIME/CLEAN
indicator.
b. Rotate
PRIME/SPRAY
Valve to
PRIME
position.
c. Press
PRIME
Button three times.
d. Plug Sprayer into 120VAC grounded GFCI outlet.
e. Turn Power Switch on. Pump will
start. If pump does not start, turn
Pressure Knob clockwise until it starts.
f. When solvent begins to flow out of
Priming Hose, turn Power Switch off.
8. Prime with paint according to
Prime
with Paint on page 13.