Page 9
For technical questions, please call 1-888-380-0318.
Item 63619
S
AFET
y
M
AINTENAN
c
E
B
ASI
c W
EL
d
IN
g
W
EL
d
IN
g T
Ip
S
SETUP
connect Shielding gas
1. With assistance, place an 100% Argon cylinder
(not included) onto a cabinet or cart near the
Welder and secure the cylinder in place with
two straps (not included) to prevent tipping.
2. Remove the cylinder’s cap. Stand to the
side of the valve opening, then open the
valve briefly to blow dust and dirt from the
valve opening. Close the cylinder valve.
3. Close the Regulator’s valve by backing off
knob until it is loose, then thread Regulator
onto cylinder and wrench tighten connection.
4. Attach the Gas Hose (included) to the
Regulator’s Outlet and the Welder’s Gas Inlet.
Wrench-tighten both connections.
Reset
Power Input
Gas Inlet
4
3
Briefly open valve
to clean,
then close
valve.
2
1
connect power cord
Plug either 120VAC or 240VAC cord
into Power Input Socket.
Note:
Plug will only fit one way.
WARNINg!
TO pREVENT SERIOUS INJURy
FROM AccIdENTAL OpERATION:
Do not
plug cord into wall outlet at this time.
Reset
Power Input
Gas Inlet
power