TROUBLESHOOTING
Follow the troubleshooting schedule below if the product stops working properly. Contact an authorised service centre if normal functionality cannot be
restored with the help of the troubleshooting schedule.
PROBLEM
POSSIBLE CAUSE
ACTION
The fork will not lift.
Low hydraulic oil level.
Check that there is no leakage. Fill up with oil.
The valve ball does not seal.
See section “Clearing the overpressure valve”.
The fork lowers by itself.
The valve ball does not seal.
See section “Clearing the overpressure valve”.
The overpressure valve is not set correctly.
Adjust the overpressure valve with the adjuster screw
until the fork hold the level.
Valve leakage.
Tighten the valves.
The fork will not lower.
The guide pin is damaged.
Replace damaged parts.
The fork frame is damaged.
Replace damaged parts.
The control lever does not stay
in neutral.
The lever (A) is not set correctly.
Adjust the lever (A) with a slotted head screwdriver.