4 - System setup
30
Table 4 - Left Channel SETUP Menus
These settings will be determined during the Automatic System Setup (“Automatic System Setup” on page 24) and
"
ReTune?
" (“Retune” on page 27) sequences automatically. However, it is possible to check and adjust these settings
manually as described below.
Automatic DeadZone Calibration
1.
Follow the steps, “STEP 1: Prepare the Equipment” on page 24 to “STEP 3: Prepare the Equipment” on page 24 (level
booms, working RPM, etc.), before proceeding.
2.
Ensure the AutoHeight panel is in MANUAL mode, at the run screen.
3.
Navigate to the "
More ?
" menu prompt in the SETUP menu. Toggle the "AUTO (YES)" switch to confirm.
4.
Navigate to the boom section you wish to set up, for example, "
Left ?
" to adjust the left up and/or the left down
settings. Toggle the "AUTO (YES)" switch to confirm.
5.
Toggle the "SETUP (NO)" switch to access the next menu prompt. Choose the dead zone up or down setting - see
“Table 4 - Left Channel SETUP Menus” on page 30.
6.
Toggle and hold the "AUTO (YES)" switch.
7.
When the "
Done
" message is displayed, release the "AUTO (YES)" switch to view the new setting.
Manual DeadZone Calibration
1.
Follow the steps, “STEP 1: Prepare the Equipment” on page 24 to “STEP 3: Prepare the Equipment” on page 24 (level
booms, working RPM, etc.), before proceeding.
2.
Ensure the AutoHeight panel is in MANUAL mode, at the run screen.
3.
Navigate to the "
More ?
" menu prompt in the SETUP menu. Toggle the "AUTO (YES)" switch to confirm.
4.
Navigate to the boom section you wish to set up, for example, "
Left ?
" to adjust the left up and/or the left down
settings. Toggle the "AUTO (YES)" switch to confirm.
5.
Toggle the "SETUP (NO)" switch to access the next menu prompt. Choose the dead zone up or down setting - see
“Table 4 - Left Channel SETUP Menus” on page 30.
6.
Toggle and hold the "MANUAL" switch.
7.
The valve will turn on at the indicated setting for exactly one second. The screen will show the actual change in height.
8.
The change in height reading is live as long as you hold the "MANUAL" switch. Wait until the height reading has settled
to a stable value and record this reading.
9.
Average your three readings. The acceptable average change in height should be from 13 to 38 mm (ideal would be
25 mm exactly).
10.
If the average is less, increase the
DZ
setting with the "+/-" switch. If the average is more, decrease the
DZ
setting with
the "+/-" switch.
11.
Repeat the Manual Dead Zone Test until the average falls into the acceptable range.
Navigating past the end of the menu will return the panel to the Setup…"
More
" Menu
Left On
Left valve channel is ON. To change the status to OFF, use the "+/-" switch (Section 6.3.5).
DZ
100
Left up DeadZone setting is 100. To adjust the reading use the "+/-" switch.
KP
53
Left up GAIN setting is 53. To adjust the reading use the "+/-" switch.
DZ
100
Left down DeadZone setting is 100. To adjust the reading use the "+/-" switch.
KP
42
Left down GAIN setting is 42. To adjust the reading use the "+/-" switch.
Navigating past the end of the menu will return the panel to the Setup…"
More
" Menu
Summary of Contents for AutoHeight
Page 5: ...5 1 Declaration This page is intentionally left blank ...
Page 6: ...1 Declaration 6 ...
Page 22: ...3 Description 22 ...
Page 46: ...5 Operation 46 ...
Page 50: ...6 Maintenance 50 ...
Page 58: ...8 Technical specifications 58 ...
Page 60: ...9 Index 60 ...
Page 62: ...HARDI INTERNATIONAL A S Helgeshøj Allé 38 DK 2630 Taastrup DENMARK ...