5 - Operation
5.8
WARNING! Always clean the sprayer carefully and immediately after use.
WARNING! Only mix chemicals in the tank according to directions given by the chemical manufacturer.
WARNING! Always clean the sprayer before changing to another chemical.
WARNING! Be careful not to slip or splash chemicals when carrying chemicals up to the tank lid!
1. Make sure the control unit is switched off.
2. Set the MANIFOLD valves to correct position. Black suction valve towards “Suction from main tank”, green valve towards
“Agitation”.
3. Engage the pump and set P.T.O. revolutions to 540 r.p.m.
4. Add the chemicals through the main tank hole.
5. When the spray liquid is well mixed, turn handle on the green pressure valve towards “Spraying” position. Keep P.T.O.
engaged so the spray liquid is continuously agitated until it has been sprayed on the crop.
The chemicals are filled through the tank lid - Note instructions on the chemical container!
Grip positions used:
Filling Liquid chemicals by HARDI FILLER
Filling chemicals through tank lid