background image

5

SUPPLEMENT TO HARDI

®

 COMMANDER        OPERATOR’S MANUAL

Electrical connections

Overall description

1. Controller (optional)
2. Spraybox II
3. To 12 Volt power supply
4. Multi-wire plug and cable
5. Junction box (on sprayer)
6. Flow transducer
7. Speed transducer

Power supply

Power requirement is 12V DC. Note polarity! The wires 
must be at least 10 awg. (4.0 mm

2

) to ensure a suf-

fi cient power supply. For the operating unit, the tractor 
circuit should have an 8 Amp fuse. The supplied power 
connector is standard on most newer tractors. If using a 
tractor with a different power connector, it is necessary 
to disassemble connector and attach the wires to the 
actual tractor connector.

Control boxes

The Spraybox and controller (optional) are fi tted in 
the tractor cabin at a convenient place. HARDI

®

 rec-

 om mends using an electric distribution box (ref. no. 
817925) to ensure a good power supply to various 12V 
attachments.

Installation of control unit brackets

The supplied tractor pillar bracket 

(A)

 has a hole spac-

ing of 3.9 in. (100mm) and 4.7 in. (120mm). Check 
tractor instructions manual for information regarding 
attachment points.

Three tubes 

(B)

 are supplied. One, two or all three may 

be used. They can be bent and shortened. A spacer 

(C)

 

is also supplied to allow further attachment possibilities. 
Find the best solution for your tractor or vehicle.

Tube 

(B)

 plate is staggered, so if correctly orientated, 

all boxes will line up.

Connect sprayer (39 pin plug) to Spraybox

When connecting the 39 pin plug from the sprayer, note 
the lock tab 

(A)

 clicks in place to secure the plug in the 

socket.

When disconnecting the plug, the metallic tab must be 
pushed back before the plug is pulled out.

Speed transducer for tractor/sprayer

Note the following if the speed transducer is fi tted to the 
tractor:

The speed transducer is an inductive type. It requires a 
metallic protrusion (e.g. bolt head) to pass by it to trig-
ger a signal. Recommended distance between protru-
sion and transducer is 1/8" to 3/16" (3 to 5 mm).

Sprayer setup

Summary of Contents for Commander Plus

Page 1: ...COMMANDER 67801103 8 10 Operator s Manual Supplement to ...

Page 2: ......

Page 3: ... right to make changes in design material or specification without notice thereof HARDI and other product names are registered trademarks of HARDI Inc in the U S and in other countries 67801103 8 10 Operator s Manual Supplement to ...

Page 4: ......

Page 5: ...res on your HARDI sprayer were suggested by growers There is no substi tute for on farm experience and we invite your comments and suggestions If any portion of this instruction book remains unclear after reading it contact your HARDI dealer or service personnel for further explanation before using the equipment For Product Service or Warranty Information Please contact your local HARDI dealer To ...

Page 6: ...be used in conjunction with the Commander Plus Operator s Manual Hardi part no 67020603 It includes setup and operating instructions for models equipped with the Spraybox II control box and 39 pin wiring The updated two year Warranty Policy has also been included Introduction ...

Page 7: ...chments Installation of control unit brackets The supplied tractor pillar bracket A has a hole spac ing of 3 9 in 100mm and 4 7 in 120mm Check tractor instructions manual for information regarding attachment points Three tubes B are supplied One two or all three may be used They can be bent and shortened A spacer C is also supplied to allow further attachment possibilities Find the best solution f...

Page 8: ...the first boom section should shut off 8 Turn the adjusting screw under the valve just turned off until the control pressure gauge again shows the same pressure as when all boom sections were open Turn the screw clockwise for higher pressure counterclockwise for lower pressure 9 Turn the boom distribution valve back on 10 Repeat steps 6 9 for the remaining boom distribu tion valves Note Hereafter a...

Page 9: ...uential damage 2 We cannot be held responsible for loss of livestock loss of crops loss because of delays in harvesting or any other expense or loss incurred for labor supplies substitute machinery rental for any other reason or for injuries either to the owner or to a third party nor can we be called upon to be responsible for labor charges other than originally agreed incurred in the removal or ...

Page 10: ...for replacement or repair by HARDI personnel before HARDI will accept any liability hereunder 10 HARDI reserves the right to incorporate any change in design in its products without obligation to make such changes on units previously manufactured 11 The judgement of the HARDI Service Department in all cases of claims under this warranty shall be final and conclusive and the purchaser agrees to acce...

Page 11: ......

Page 12: ...1A6 Phone 519 659 2771 Fax 519 659 2821 For Product Service or Warranty Information Please contact your local HARDI dealer To contact HARDI directly Please use the HARDI Customer Service number 1 866 770 7063 Or send your email to CUSTSERV hardi us com HARDI NORTH AMERICA INC Visit us online at www hardi us com ...

Reviews: