7 - Fault finding
7.4
Insufficient power supply.
CONTROL/REMEDY
Insufficient hydraulic pressure.
Voltage on activated solenoid valve must be more than 8
Volts. Use wires of at least 4 mm for power supply.
Wrong oil inlet to by-pass block.
By-pass valve 0 does not close properly.
Clogged restrictor.
PROBABLE CAUSE
Check oil pressure - min. 130 bar, max. 160 bar.
Check tractor hydraulic oil level.
Defect relay / diodes in junction box.
Connect hydraulic snap couplers opposite in tractor outlets, or
engage spool valve lever in opposite direction.
Check / close (screw in) by-pass valve 0.
Dismantle and clean restrictor.
Hydraulic system - Z model
No boom movements when activated.
Check relays, diodes and soldering at PCB in junction box.
Boom lift raises to max. pos. when trac-
tor hydraulics are engaged.
Oil heats up in Closed Centre systems.
Individual ram does not move.
FAULT
Insufficient oil supply.
Clogged restrictors a or b in by-pass block.
Back pressure in return line exceeds 20 bar.
Internal leaks in flow regulator.
Oil flow must be min. 10 l/min. and max. 90 l/min.
Check tractor hydraulic oil level.
Remove and clean restrictors a and b in bypass block (See
hydraulic diagram) Change hydraulic oil + filter.
Connect the return line with free flow to hydraulic oil reser-
voir.
Divide return line in two and lead return oil back to reservoir
via two spool valves.
Replace flow regulator O-rings and back-up rings. Replace
flow regulator.
Blown fuse(s).
Wrong polarity.
Check / replace fuse in junction box.
Check polarity. White pos. (+) Blue neg. (-).
Bad / corroded electrical connections.
Check / clean connections, multi plugs etc.
Summary of Contents for COMMANDER TWIN FORCE 3200
Page 8: ...Table of contents TOC 6 ...
Page 10: ...1 CE Declaration 1 2 ...
Page 14: ...2 Safety notes 2 4 ...
Page 66: ...6 Maintenance 6 2 Boom lubrication oiling plan 32 36 m ...
Page 67: ...6 Maintenance 6 3 Trailer lubrication oiling plan ...
Page 107: ...8 Technical specifications 8 11 Charts Boom hydraulic Y Boom hydraulic Z ...
Page 108: ...8 Technical specifications 8 12 Sprayer hydraulic Fan transmission ...
Page 109: ...8 Technical specifications 8 13 Electrical specifications for boom and work light ...
Page 110: ...8 Technical specifications 8 14 ...