23
Method
1. Measure a distance not less than 75 metres.
2. Park the tractor at the start of the measured distance.
3. Open menu. When zero distance [ 0 m ] shows, drive the meas-
ured distance.
4. Correct the distance shown on the display with the arrow key to
read the actual distance
Revolutions calibration
For calibration of revolutions transducer.
The constant, pulse per revolution (PPR), is
the number of pulses for one revolution.
For example, if one magnet is fitted, the PPR is 1.0.
Alarms
There are 2 alarms, a tank alarm for low tank contents and a volume
rate alarm for over or under application. When outside the alarm
parameters, the relevant warning will flash. A beeper can also be
activated.
Low tank contents alarm.
P R A C T I C A L
M e a s u r e d x x x m
C A L I B R A T I O N
R e v o l u t i o n s c a l .
R E V O L U T I O N S C A L .
x . x P P R
A L A R M S
T a n k a l a r m