7 - Fault finding
68
Hydraulic system - H/Y model
FAULT
PROBABLE CAUSE
CONTROL/REMEDY
Boom slow/eradic.
Air in system.
Loosen ram connection and activate hydraulics until
oil flow has no air in it (not whitish).
Regulation valve incorrectly set.
Open or close until desired speed is achieved
(clockwise = less speed).
Remember oil must be at operating temperature.
Insufficient hydraulic pressure.
Check output pressure of tractor hydraulics. Minimum
for sprayer is 170 bar.
Insufficient amount of oil in tractor reservoir.
Check and top if needed.
Ram not functioning.
Restrictor or regulation valve blocked.
Secure boom. Dismantle and clean.
Hydraulic system fold/tilt functions will not operate. Power supply.
Check for proper 12V power supply.
One function (fold or tilt) will not operate.
Various.
Check for defective switch(s).
Check continuity of cables.
Check for operation of applicable solenoid (coil not
activating or plunger stuck).
Check for short circuit in wiring junction box at rear of
sprayer.
Dirt in the restrictor port of the cylinder.
Multiple hydraulic functions with one switch
activated.
Various.
Check for correct solenoid electric/hydraulic hook-up.
Check for short circuit in wiring in the junction box at
rear of sprayer.
Summary of Contents for MASTER PRO VHH
Page 6: ...Table of Contents 6 ...
Page 8: ...1 EC Declaration 8 ...
Page 12: ...2 Safety notes 12 ...
Page 50: ...5 Operation 50 ...
Page 52: ...6 Maintenance 52 Boom lubrication oiling plan Lift lubrication oiling plan ...
Page 70: ...7 Fault finding 70 ...
Page 76: ...8 Technical specifications 76 Charts Boom hydraulic Z ...
Page 78: ...8 Technical specifications 78 ...
Page 82: ...HARDI INTERNATIONAL A S Helgeshøj Allé 38 DK 2630 Taastrup DENMARK ...