6 - Maintenance
136
Adjustment of 3-Way Valve
The large ball valve used for SmartValves and valves for filling equipment
(type s93) can be adjusted, if it is too tight to operate - or if it is too loose
(= liquid leakage).
•
Correct setting is when the valve can be operated smoothly by one
hand.
Use a suitable tool and adjust the toothed ring inside the valve as shown
on the drawing.
ATTENTION! The small ball valves (type s67) cannot be adjusted.
Safety Valve Activation
To make the fluid system work perfectly over time, it is good practice to regularly provoke opening of the safety valve.
This prevents clogging and ensures proper function of the safety valve. Opening of the valve is done by turning the pressure
SmartValve to an unused function, when the pump is running. This is good practice for all sprayers; particularly for sprayers
without optional equipment.
€
DANGER! Before turning pressure the SmartValve to “Pressure draining”, it is very important to be sure that the quick
coupler lid is correctly and completely mounted to the filling stud in its locked position. Failure to do so causes a risk
of contamination and injury from the quick coupler lid being “shot” off when pressurized! If it is not possible to mount
lid completely, lubricate the rubber seal and the grip hooks.
Summary of Contents for MEGA VPZ MASTER
Page 4: ...1 EU Declaration 4...
Page 10: ...Table of Contents 10...
Page 42: ...2 Safety Notes 42...
Page 68: ...3 Description 68...
Page 118: ...5 Operation 118...
Page 121: ...6 Maintenance 121 Lubrication Plan Boom Centre Close up of Glide Shoes to be Lubricated...
Page 172: ...8 Technical Specifications 172...
Page 176: ...Index 176...
Page 178: ...HARDI INTERNATIONAL A S Herthadalvej 10 DK 4840 N rre Alslev DENMARK...