3 - Description
65
Tank Level Indicator
Main Tank
The position of the lever (A) on the scale indicates the actual liquid level,
as the lever is connected to a float inside the tank.
The scale is displayed in litres - multiply by 100 for the reading.
Example: The lever stands at 6 on the scale; this means 600 litres left in
the tank.
The total deviation of accuracy for the level for each scale mark or
readout value is:
± 15 % for volumes up to 10 % of the nominal tank volume.
± 7.5 % for volumes between 10 and 20 % of the nominal tank volume.
± 5 % for volumes above 20 % of the nominal tank volume.
RinseTank
The position of the lever (B) on the scale indicates the actual liquid level,
as the lever is connected to a float inside the tank.
The scale is displayed in litres - multiply by 10 for the reading.
Example: The lever stands at 10 on the scale; this means 100 litres left in
the tank.
ATTENTION! The level indicators for both tanks are only a
guidance for the liquid level in the tank.
For the most accurate reading, park the vehicle on horizontal ground.