6 - Maintenance
98
After storage
After a storage period the sprayer should be prepared for the next season the following way:
1.
Remove the cover.
2.
Remove the support from the wheel axle and adjust tyre pressure.
3.
Wipe off the grease from hydraulic ram piston rods.
4.
Fit the pressure gauges again. Seal with Teflon tape.
5.
Connect the sprayer to the tractor including hydraulics and electrics.
6.
Check all hydraulic and electric functions.
7.
Empty the tank for remaining anti-freeze.
8.
Rinse the entire liquid circuit of the sprayer with clean water.
9.
Fill with clean water and check all functions.
10.
Check function of brakes. Please note that brake power will be reduced until the rust are worn off the drums. Always
brake lightly until the drums are clean.
Summary of Contents for NAVIGATOR DELTA