3 - Description
22
CycloneFilter
With the CycloneFilter, any impurities in the spray liquid will by-pass the
filter and be re-circulated back to the tank via the return flow.
Function diagram
1.
Filter lid
2.
From pump
3.
To boom
4.
Return to tank
5.
Return valve
The valve (5) has three positions marked with small dots on the lever:
A.
This position marked with 1 dot: There is no return flow. Position is
used when rinsing the boom, if there is spray liquid in the main
tank. Also used when high spraying volume is required.
B.
This position marked with 2 dots: Normal spraying position. With
return flow to prevent filter is going to be clogged when spraying.
This position is used when rinsing the boom, if the main tank is empty.
C.
This position marked with 3 dots: Flushing position which is used if filter is clogged. Lift and hold the lever to use this
position, which largely increases return flow and flushes the filter. The pressure SmartValve must be set to “Spraying”.
μ
ATTENTION! Use of position C is no guarantee for a clean filter. Always regularly do a visual inspection and cleaning
of the filter. If necessary, see “10 Hours Service - CycloneFilter” on page 79.
€
DANGER! Never open the Cyclone filter unless the suction valve
is closed and the pressure SmartValve is turned to “Main tank”.
Otherwise, spraying liquid may hit you, when opening the filter,
and thereby draining the main tank!
Summary of Contents for NAVIGATOR FORCE
Page 4: ...1 EU Declaration 4 ...
Page 12: ...2 Safety Notes 12 ...
Page 54: ...4 Sprayer setup 54 ...
Page 76: ...6 Maintenance 76 Boom lubrication oiling plan ...
Page 112: ...8 Technical specifications 112 ...
Page 116: ...Index 116 ...
Page 118: ...HARDI INTERNATIONAL A S Herthadalvej 10 DK 4840 Nørre Alslev DENMARK ...