5 - Operation
106
Filling the RinseTank
The RinseTank is filled via the 1” threaded connection piece (A):
1.
Remove the filler cap, then fit the external water hose to the
threaded connection piece.
2.
Start filling with tap water.
3.
Keep an eye on the level indicator in order not to overfill the tank.
4.
Stop filling and refit the cap.
Volume: approximately 500 litres.
μ
ATTENTION! Only fill the RinseTank with clean water! To avoid
algae developing in the tanks. Always drain the RinseTank, if the
sprayer is not in use for a longer period of time.
μ
ATTENTION! For cleaning and inspection purpose, the RinseTank
is accessible via the tank lid on top of the tank.
Filling the CleanWaterTank
To fill the CleanWaterTank:
1.
Remove the tank lid.
2.
Fill with clean water.
3.
Refit the tank lid.
For use of water:
•
Turn the lever to open the ball valve. The ball valve is located on
the left side of the sprayer next to the EasyCleanFilter.
The water from this tank is for hand washing, cleaning of clogged nozzles etc.
±
WARNING! Although the CleanWaterTank is only filled with clean water, this water must NOT be used for drinking.
μ
ATTENTION! Only fill the CleanWaterTank with clean water! To avoid algae developing in the tank. Always drain the
CleanWaterTank, if the sprayer is not in use for a longer period of time.
Summary of Contents for NAVIGATOR VPZ
Page 4: ...1 EU Declaration 4...
Page 72: ...3 Description 72...
Page 135: ...6 Maintenance 135 Lubrication Plan Boom Wings 10...
Page 174: ...6 Maintenance 174...
Page 182: ...7 Fault Finding 182...
Page 195: ...8 Technical Specifications 195 Hydraulic Diagrams Hydraulics for Boom of 21 24 Meters...
Page 196: ...8 Technical Specifications 196 Hydraulics for Boom of 27 28 Meters...
Page 198: ...8 Technical Specifications 198...
Page 204: ...HARDI INTERNATIONAL A S Herthadalvej 10 DK 4840 N rre Alslev DENMARK...