16
HARDI
®
New NAVIGATOR OPERATOR’S MANUAL
Operation
ECPC PLUMBING DIAGRAM (for centrifugal pump systems)
The HARDI
®
New NAVIGATOR trailer sprayer is available with either diaphragm or centrifugal
plumbing systems. Take time to re view and study the plumb ing di a gram for your sprayer. By
fol low ing the fl ow through the diagram, you will better un der stand the var i ous func tions of your
spray er system.
1. Bottom Suction Valve
2. Suction manifold
3. Pump
4. Pressure manifold
5. Agitation
6. HARDI-MATIC
7. Boom section valves
8. Boom
9. Boom pressure gauge
10. Flush tank
11. Quick fi ll
12. Variable Agitation manifold
13. Pressure equalization return
14. HARDI
®
chemical inductor
15. Tank rinse nozzles
16. Check valves
2
5
5
13
8
9
10
14
15
15
1
3
6
7
16
16
11
4
12