8 - Technical Specifications
110
Other Specifications
Tractor Requirements
Power Take-Off
Hydraulic System
* Depending on scope of supply.
€
DANGER! If one or more the values are exceeded, this may cause damages and sudden leaks on the sprayer. Risk of
injuries and fatal accidents.
Voltage
Power Consumption
Recommended tractor engine output are as follows.
Temperature and Pressure Ranges
Spray Liquid System
Min. / Max. operating torque
See type sign for liquid pump (kW).
The type sign is located on the back side of the pump,
facing pointing away from the tractor.
Max. operating temperature
80 °C
Max. operating pressure from the tractor
210 bar
Min. operating pressure from the tractor
180 bar
Max. flow from tractor
120 l/min
Min. flow from tractor @ 200 bar
15 - 80 l/min *
Max. oil filter rating
10 μm
Voltage
12 V DC
Tolerance for voltage
- 1.5 V / + 3.0 V
Current
40 A peak
Main tank volume (litres)
Output (hp)
Output (kW)
400
70
51
600
85
62
800
100
73
Operating temperature range
2 - 40 °C
Operating pressure for the safety valve
15 bar ± 1 bar
Max. pressure on the pressure manifold
20 bar
Max. pressure on the suction manifold
1.5 bar
Summary of Contents for NK MB Series
Page 8: ...1 Identification 8 ...
Page 52: ...3 Description 52 ...
Page 62: ...4 Sprayer Setup 62 ...
Page 84: ...5 Operation 84 ...
Page 87: ...6 Maintenance 87 Boom Lubrication Oiling Plan Lift Lubrication Oiling Plan ...
Page 116: ...9 EC Declaration 116 ...
Page 120: ...Index 120 ...
Page 122: ...HARDI INTERNATIONAL A S Helgeshøj Allé 38 DK 2630 Taastrup DENMARK ...