3 - Description
3.7
CycloneFilter
With the CycloneFilter, the impurities that exist in the spray liquid will by-
pass the filter and be recirculated back to the tank via the return flow.
Function diagram
1
.
Filter lid
2.
From pump
3.
To boom
4.
Return to tank
5
.
Return valve
Valve (5) has three positions marked with small dots on the lever:
Position A (Marked with 1 dot): There is no return flow. Position is used
when flushing the boom if there is spray liquid in the main tank. Also
used when high spraying volume is required.
Position B (Marked with 2 dots): Normal spraying position. With return
flow to prevent clogging the filter when spraying. Position is used when
flushing the boom if the main tank is empty.
Position C (Marked with 3 dots): Flushing position, which is used if filter
is clogged. Lift and hold the lever to use this position which largely
increases return flow and cleans the filter.
See Maintenance section for service of filter.
€
DANGER! Never open the CycloneFilter unless the top green
pressure manifold valve and bottom black suction manifold valve
are both closed (turned to the unused position). Otherwise,
spraying liquid could hit you when opening the filter, and drain
from the tank!