5 - Operation
50
Filling powder chemicals by HARDI TurboFiller (optional)
1.
Fill the main tank at least 1/2 with water (unless otherwise stated
on the chemical container label). See section “Filling of water”.
2.
Turn the handle of the suction valve towards “suction from Main
tank”. Turn pressure valve to closed position. Turn the
AgitationValve towards “Agitation” if required. Close remaining
valves.
μ
ATTENTION! For increased suction from the TurboFiller the
AgitationValve can be kept closed.
÷
NOTE! If filling water from an external tank, this can be continued
while doing the next steps.
3.
Engage the pump and set P.T.O. speed at 540 r/min or 1000 r/min
(depending on pump model).
4.
Open TurboFiller lid. Open TurboDeflector valve and TurboFiller
suction valve.
5.
Measure the correct quantity of chemical and sprinkle it into the hopper as fast as the transfer device can flush it down.
The TurboFiller suction valve must be open for at least 20 seconds after the chemical is no longer visible in the hopper
in order to completely empty the transfer hoses into the main tank.
€
DANGER! If the TurboFiller and the transfer hoses are not completely emptied there are risk of chemicals being
siphoned out of the main tank!
€
DANGER! Always wear face shield and other appropriate personal safety equipment when filling chemicals.
6.
If the chemical container is empty, it can be rinsed by the Chemical Container Cleaning device. Place the container
over the multi-hole nozzle and push the upper lever to the left of the TurboFiller.
€
DANGER! In order to avoid spray liquid hitting the operator, do not press lever unless the multi-hole nozzle is covered
by a container as spray liquid may otherwise hit the operator.
μ
ATTENTION! Rinsing device uses spray liquid to rinse containers for concentrated chemicals. Always rinse the
chemical containers with clean water several times until they are clean before disposal.
7.
Flush the TurboFiller with clean water from the Rinsing tank. The TurboFiller suction valve must be open for at least 20
seconds after the rinse water is no longer visible in the hopper in order to completely empty the transfer hoses into
the main tank.
μ
ATTENTION! If not flushed with clean water, the hopper rinsing device uses spray liquid for rinsing the hopper!
Cleaning the TurboFiller must always be done when the spray job is ended and together with the entire sprayer - a
cleaning after the last filling and before spraying the last tankful does not ensure a clean TurboFiller!
Summary of Contents for RANGER EAGLE
Page 8: ...1 EC Declaration 8 ...
Page 12: ...2 Safety notes 12 ...
Page 26: ...3 Description 26 ...
Page 40: ...4 Sprayer setup 40 ...
Page 60: ...5 Operation 60 ...
Page 84: ...6 Maintenance 84 ...
Page 95: ...8 Technical specifications 95 Charts Boom hydraulic Z Boom hydraulic Y ...
Page 96: ...8 Technical specifications 96 ...
Page 100: ...HARDI INTERNATIONAL A S Helgeshøj Allé 38 DK 2630 Taastrup DENMARK ...