3 - Description
20
CycloneFilter (optional)
With the CycloneFilter any impurities in the spray liquid will by-pass the
filter and be re-circulated back to the tank via the return flow.
Function diagram
1.
Filter lid
2.
From pump
3.
To boom
4.
Return to tank
5.
Return valve
Valve (5) has three positions marked with small dots on the lever:
A.
This position marked with 1 dot: There is no return flow. Position is
used when rinsing the boom if there is spray liquid in the main
tank. Also used when high spraying volume is required.
B.
This position marked with 2 dots: Normal spraying position. With
return flow to prevent filter is going to be clogged when spraying.
This position is used when rinsing the boom if the main tank is empty.
C.
This position marked with 3 dots: Flushing position which is used if filter is clogged. Lift and hold the lever to use this
position which largely increases return flow and flushes the filter. The top green pressure valve must be set to
“Spraying”.
μ
ATTENTION! Use of position C is no guarantee for a clean filter. Always regularly do a visual inspection and cleaning
of the filter. If necessary see “10 hours service - Cyclone Filter” on page 64.
€
DANGER! Never open the Cyclone filter unless the top green
pressure manifold valve and bottom black suction manifold valve
are both closed (turned to the unused position). Otherwise,
spraying liquid may hit you when opening the filter, and drain
from the main tank!
Summary of Contents for RANGER EAGLE
Page 8: ...1 EC Declaration 8 ...
Page 12: ...2 Safety notes 12 ...
Page 26: ...3 Description 26 ...
Page 40: ...4 Sprayer setup 40 ...
Page 60: ...5 Operation 60 ...
Page 84: ...6 Maintenance 84 ...
Page 95: ...8 Technical specifications 95 Charts Boom hydraulic Z Boom hydraulic Y ...
Page 96: ...8 Technical specifications 96 ...
Page 100: ...HARDI INTERNATIONAL A S Helgeshøj Allé 38 DK 2630 Taastrup DENMARK ...