3 - Description
21
TurboFiller (optional)
Before use
•
Push the handle (A) to unlock.
•
Grab the handle to pull TurboFiller down (B) until it clicks into
locked down-position.
After use
•
Pull the handle (A) to unlock.
•
Grab the handle to pull TurboFiller back in storing position until it
locks.
±
WARNING! Before releasing the lock (A) always keep a hand on
the grip to avoid abrupt movement of the TurboFiller!
TurboFiller suction valve
The valve is used simultaneously with the TurboFiller. The valve has 2
settings: Continuously open or spring loaded normally closed. Open the
valve when chemicals are to be filled into the TurboFiller and transferred
to main tank.
TurboDeflector valve
This TurboDeflector valve activates the Vortex flushing of the TurboFiller.
Lift the lever to lock it in open position for continuous liquid rotation in
the hopper.
Chemical Container Rinsing lever
The upper lever is used for two purposes:
When the TurboFiller lid is open: For rinsing empty containers. Place the
container over the rotating flushing nozzle in the middle of the
TurboFiller to rinse the inside of the container.
When the TurboFiller lid is closed: Use the Chemical Container Rinsing
lever to rinse the hopper when the filling of chemicals is completed.
€
DANGER! Do not press the lever unless the multi-hole nozzle is covered by a container as spray liquid may otherwise
hit the operator.
Suction from TurboFiller
Start TurboDeflector
Chemical Container Rinsing
Summary of Contents for RANGER EAGLE
Page 8: ...1 EC Declaration 8 ...
Page 12: ...2 Safety notes 12 ...
Page 26: ...3 Description 26 ...
Page 40: ...4 Sprayer setup 40 ...
Page 60: ...5 Operation 60 ...
Page 84: ...6 Maintenance 84 ...
Page 95: ...8 Technical specifications 95 Charts Boom hydraulic Z Boom hydraulic Y ...
Page 96: ...8 Technical specifications 96 ...
Page 100: ...HARDI INTERNATIONAL A S Helgeshøj Allé 38 DK 2630 Taastrup DENMARK ...