5 - Operation
97
Cleaning the Tank and Liquid System
μ
ATTENTION! Thorough cleaning of the sprayer is to be carried out when shifting to crops, which are very sensitive to
chemicals just sprayed, or prior to storage for a longer period of time.
÷
NOTE! Prior to the described cleaning, a standard cleaning should be carried out.
•
Select and use the appropriate protective clothing. Select detergent suitable for cleaning and suitable deactivating
agents if necessary.
•
Rinse and clean sprayer and tractor externally. Use detergent if necessary.
1.
Remove tank filters and suction filters and clean the sprayer. Be careful not to damage the filter mesh. Put back the
suction filter top. Put back all filters, when the sprayer is completely clean.
2.
With the pump running, rinse the inside of the tank. Do not forget to clean the tank roof. Rinse and operate all
components and any equipment, which have been in contact with the chemical. Before opening the distribution
valves and spraying the liquid out, decide whether this should be done in the field or on the seepage location.
3.
After spraying the liquid out, stop the pump and fill at least 1/5 of the tank with clean water. Note that some chemicals
require the tank to be completely filled. Add appropriate detergent and/or deactivating agent, e.g. washing soda or
triple effect ammonia. Special detergents for sprayer cleaning is recommended as some also lubricate ball valves etc.
4.
Start the pump and operate all controls enabling the liquid to come into contact with all the components. Operate
the distribution valves as the last thing. Some detergents and deactivating agents work best, if they are left in the tank
for a short period. Check the label.
5.
Drain the tank and let the pump run dry. Rinse inside of the tank, again letting the pump run dry.
6.
Stop the pump. If the pesticides used have a tendency to block nozzles and filters, remove and clean them
immediately.
7.
Put back all the filters and nozzles and store the sprayer. If it is noted, from previous experiences, that the solvents in
the pesticides are particularly aggressive, store the sprayer with the tank lid open.
μ
ATTENTION! It is advisable to increase the forward speed (double, if possible) and reduce the spraying pressure to 1.5
bar, when spraying diluted remaining liquid in the field just sprayed.
μ
ATTENTION! If a cleaning procedure is given on the chemical label, follow it closely.
μ
ATTENTION! If the sprayer is cleaned with a high pressure washer, lubrication of the entire machine is recommended.
Summary of Contents for RANGER PRO VH
Page 4: ...1 EU Declaration 4 ...
Page 10: ...Table of Contents 6 ...
Page 108: ...5 Operation 104 ...
Page 111: ...6 Maintenance 107 Boom Lubrication Oiling Plan Lubrication Oiling Plan Trailer Paralift ...
Page 142: ...6 Maintenance 138 ...
Page 164: ...Index 160 ...
Page 166: ...HARDI INTERNATIONAL A S Herthadalvej 10 DK 4840 Nørre Alslev DENMARK ...