8 - Technical Specifications
147
Voltage
The sprayer is designed for the following voltage only:
* The blade fuses usually allow up to 50 A for a few seconds before blowing.
€
DANGER! If the tolerances for voltage are exceeded, the electrical system can fail. Risk of fire. Risk of defect or
malfunctioning components.
Power Consumption
Recommended tractor engine output are as follows.
•
End of tractor requirements.
Temperature and Pressure Ranges
Spray Liquid System
Brakes
Max. wear rates on brake components:
Pressure settings for the load apportioning valve:
€
DANGER! If one or more the values are exceeded, this may cause damages and sudden leaks on the sprayer. Risk of
injuries and fatalities.
Voltage
12 V DC. Tolerance: -1.5/+3.0 V DC.
Tolerance for voltage
- 1.5 V / + 3.0 V
Current from tractor
40 A peak
Blade fuses on the sprayer
25 A *
Main tank volume (litres)
Output (hp)
Output (kW)
2500
82
60
Operating temperature range
2 - 40 °C
Operating pressure for the safety valve
15 bar ± 1 bar
Max. pressure on the pressure manifold
20 bar
Max. pressure on the suction manifold
1.5 bar
Sprayer volume
Drum dimensions
Max. drum diameter
Min. lining thickness
25003300 litres
400 x 80 mm
403 mm
4.0 mm
Situation
Pressure in air tank
Released
0 bar
Empty main tank
2.8 bar
Half main tank
4.3 bar
Full main tank
Max. pressure (6.5 bar)
10.5
15.0
12
Summary of Contents for RANGER PRO VH
Page 4: ...1 EU Declaration 4 ...
Page 10: ...Table of Contents 6 ...
Page 108: ...5 Operation 104 ...
Page 111: ...6 Maintenance 107 Boom Lubrication Oiling Plan Lubrication Oiling Plan Trailer Paralift ...
Page 142: ...6 Maintenance 138 ...
Page 164: ...Index 160 ...
Page 166: ...HARDI INTERNATIONAL A S Herthadalvej 10 DK 4840 Nørre Alslev DENMARK ...