109
8 - Technical specifications
363/7
r/min
300
400
500
540
600
700
bar
l/min
kW
l/min
kW
l/min
kW
l/min
kW
l/min
kW
l/min
kW
0
78
0,90
104
1,20
131
1,60
140
1,60
156
1,90
183
2,20
2
76
1,00
102
1,30
128
1,70
136
1,80
152
2,00
177
2,30
4
74
1,30
98
1,50
125
1,90
133
2,10
147
2,40
170
2,80
6
73
1,40
97
1,80
121
2,30
130
2,50
144
2,90
167
3,50
10
71
1,80
95
2,40
117
3,10
127
3,40
141
3,80
164
4,60
15
70
2,40
92
3,20
115
3,90
124
4,40
137
5,00
161
5,90
20
68
2,90
90
3,90
113
4,80
122
5,40
135
5,90
158
7,00
Maximum pressure: 20 bar
Weight: 52,6 kg
Normal working revolutions: 540 r.p.m
363/7 Diaphragm
Filters and nozzles
Filter mesh width
30 mesh: 0.58 mm
50 mesh: 0.30 mm
80 mesh: 0.18 mm
100 mesh: 0.15 mm
Temperature and pressure range
Working temperature range: 2º – 40º C. (36ºF – 104ºF)
Pressure that activates the safety valve: 20 bar in HLC and 40 bar in HPC
Maximum pressure in the pressure valve: 20 bar in HLC and 40 bar in HPC
Maximum pressure in the suction valve: 7 bar