background image

2

16C Low-Pressure Dead-Length Collet Blocks

 Instructions B-145

Hardinge Inc.  One Hardinge Drive, Elmira, New York U.S.A. 4902-507  800.843.880 (Canada 800.468.5946)   www.hardingetooling.com

Par

t No

. B -0009500-0

45

 

COLLET

LOCKING

SCREW

4.000''

(101.6mm)

4.000''

(101.6mm)

1.062''

(26.9mm)

1/4-18 NPT

SUPPLY PORTS

2X

1/4-20 MOUNTING

HOLES, 4X

.375 (17.1mm) DOWEL 

LOCATING HOLES, 2X

3.000''

(76.2mm)

2.8750''

(73.0mm)

+.0010

-.0000

+.0254

-.0000

1.4375''

(36.5mm)

+.0005

-.0000

+.0127

-.0000

3.625''

(92.0mm)

1.125''

(28.5mm)

4.000''

(101.6mm)

4.250''

(107.9mm)

1.094''

(27.7mm)

CONNECTOR BUSHING PORTS, 4X

TOP 

VIEW

BOTTOM 

VIEW

4.  Using the collet wrench, turn the collet clockwise until it contacts the piston taper.
5.  Tighten the collet locking screw. Do not overtighten.
6.  To close the collet closer, insert a workpiece in the collet, and connect the supply to the control valve. 

WARNING: 

 

Do not close the closer without the workpiece in the collet.

7.   Adjust your supply pressure to a level that assures effective workholding only. Continuously operating the closer at  

maximum pressure will decrease the service life of the seals and collet. 

WARNING:  Pressure to this closer above 250 psi air or 207 psi hydraulic (7 bar air, 83 bar hydrualic) 
may overstress the 5C collet.

8.  To open the collet, actuate the valve.

Maintenance

If, over a period of time, you experience a decrease in clamping force even though pneumatic or hydraulic pressure remains 
unchanged, remove the collet block from service, disassemble, and replace any damaged or worn o-rings.

Warranty

The products furnished hereunder are guaranteed by Hardinge Inc. against any defect in material or workmanship for a 
period of one (1) year from date of shipment when owned by original buyer or first user, and maintained and operated 
under normal conditions. Any products hereunder not manufactured by Hardinge Inc. are warranted only to the extent of 
the original manufacturer’s warranty. Parts found to be defective in material or workmanship under this guaranty shall be 
repaired or replaced without charge, F.O.B., original point of shipment provided prompt notice of the defect is given and 
compliance with the terms of this guaranty are established. HARDINGE INC. SHALL BE LIMITED STRICTLY AND  
WHOLLY TO THE FOREGOING.

In no event shall Hardinge Inc. be liable for consequential or incidental damages or for other costs, expenses, or damages 
incurred by you attributed to any item sold hereunder. 

Summary of Contents for 16C

Page 1: ...ssure of 250psi air or 1207 psi hydraulic 17 bar air 83 bar hydraulic Make sure that the collet retains your material when the closer is closed Application This 16C collet block is a stationary unit with a double acting cylinder It is effective on machine and assembly operations that require reliable clamping and unclamping Use the collet block as a single unit or mount multiple closers on rotary ...

Page 2: ...to this closer above 250 psi air or 1207 psi hydraulic 17 bar air 83 bar hydrualic may overstress the 5C collet 8 To open the collet actuate the valve Maintenance If over a period of time you experience a decrease in clamping force even though pneumatic or hydraulic pressure remains unchanged remove the collet block from service disassemble and replace any damaged or worn o rings Warranty The prod...

Page 3: ...ting AIR SUPPLY FIXTURE PLATE Example of a simple pneumatic configuration Components include a control valve and three pneumatic collet blocks supplied by Hardinge mounted on a customer machined fixture plate Two connector bushings are used between each collet block for internal plumbing A total of four connector bushings would be used in this example schematic shown in clamp position Dimensions f...

Page 4: ...mp control valve and three hydraulic collet blocks supplied by Hardinge mounted on a customer machined fixture plate schematic shown in clamp position 5000 psi 344 bar rated hose tubing is recommended Dimensions for mounting holes are available on the installation instructions online at www hardingetooling com Example of a quick disconnect hydraulic configuration Components include a pump control ...

Reviews: