Any-Weigh™ Series Floor Scales
22
Step 3.
Use a small slotted head screw driver and
disconnect the Load Sensor cable. It is a
good idea to mark the wires if the wire
markers have been removed. Color code
wires are as follows:
•
+ Excitation
Red
•
+ Signal
Green
•
- Signal
White
•
- Excitation
Black
•
+ C2
Grey
•
- C2
Violet
Step 4.
Loosen the cord grip nut for the load sen-
sor cable you want to remove. (See Fig.
19)
Load Sensor #
Connector
Load Sensor #1
TB1
Load Sensor #2
TB2
Load Sensor #3
TB3
Load Sensor #4
TB4
To Instrument
TB5
Table 3: Summing Card Load Sensor Connectors