HARDY MANUFACTURING CO., INC (MODEL H3, H5, & H6) PAGE 24
Section V 5-2
Option 2 – Plate Heat Exchanger for Domestic Hot Water
located on rear of Heater
When this option is ordered a Taco 008 pump is installed on the rear of the heater. A plate
heat exchanger will be mounted directly below the pump, and will be connected to the
pump with a stainless steel flex line. This pump will be wired to run continuously.
The domestic water hooks up on the opposite side of the plate heat exchanger. The
direction of domestic water flow is reversed from that of the heater water flow. The cold
water supply will go into the bottom port and the hot water back to the home hot water
heater will connect to the top port.
!
DANGER
WATER TEMPERATURE
OVER 125° CAN CAUSE
SEVER BURNS INSTANTLY
Summary of Contents for H3