Plumbing Connections
Connection to Heating System
1. The pipe that will supply the heating system is connected on the lower side of the
pump ( Item 1).
2. The pipe that will carry the return water from the heating system is connected to the
1” fitting as shown in diagram below ( Item 2 ).
Existing
Boiler
Heat
Zone
Heat
Zone
Existing
Pump
Close this valve
Heater with hull and stacks
removed to show connections
Hardy
P/N 300.01
40 Plate Heat
Exchanger
with 1" fittings
1
2
Taco 009
Taco 008
Return
Supply
Water pipes must be designed for hot water service (ex. copper, cpvc, or Pex A).
Pipes should be installed in a 4” water tight pipe or some other type of insulating
means to prevent heat loss from heater to heating system. Use only copper,
brass, or stainless steel fittings. Do not use galvanized or black iron.