HARDY MANUFACTURING CO., INC (MODEL KB165) PAGE 31
10-1 Water Solenoid Valve
Step #
Operation Description
Visual Aids/Comments
1
If you are replacing only the water fill solenoid coil, cut wires to
automatic water fill approx. 4" to 6" from solenoid coil.
2
Firmly pull solenoid coil away from valve as shown.
3
To continue in changing the whole water fill assembly, you need to
use an adjustable wrench and a back up wrench. Note: the fitting
above the valve is a swivel fitting and can be turned to remove
valve.
4
Remove the 1/2" ball valve, the 1/4" X 1/2" brass bushing, and the
1/4" close nipple from old valve.
!
Hazardous Voltage! Disconnect Power to
Heater prior to performing this
maintenance operation.