HARDY MANUFACTURING CO., INC (MODEL KB165) PAGE 36
10-3 Pump (continued)
Step #
Operation Description
Visual Aids/Comments
Testing Pump Capacitor
1
Remove top cover to expose electrical connections.
2
If using an analog Ohm meter, check the resistance across the
two capacitor leads. The meter should immediately read "0"
Ohms then slowly drift to infinity. Reverse the test leads and
check meter reading. The test procedure is the same for a digital
multimeter except the meter will show some resistance then return
to "OL" (open line). To replace Capacitor, cut away existing wire
nut connectors. Strip leads and connect with wire nut connector
suitable for two(2) 16 AWG wires.
3
Replace cover.
Testing Pump Motor Winding
1
Disconnect power cord from motor wiring. Using an Ohm meter
or continuity tester, check the continuity across each power wire
and also check each power wire to ground. If the the pump does
not show continuity across the two power wires or if either power
wire shows continuity to ground the winding is defective and the
pump should be replaced.
!
Hazardous Voltage! Disconnect Power to
Heater prior to performing this
maintenance operation.