HARDY MANUFACTURING CO., INC (MODEL KB165) PAGE 45
10-10 Bypass Damper
Step #
Operation Description
Visual Aids/Comments
1
Open the Bypass damper.
2
Open the flue box door on the right side of the heater.
3
Remove the pin clip on the damper arm where it is connected to
the pull rod connectors.
4
Pull the pin out of the damper arm.
!
Hazardous Voltage! Disconnect Power to
Heater prior to performing this
maintenance operation.