HARDY MANUFACTURING CO., INC (MODEL LC300, LC500 & LC2500)
PAGE 42
8-1
GENERAL TROUBLE SHOOTING GUIDE (continued)
COMPLAINT
AREA OF TROUBLE
POSSIBLE CAUSE
CORRECTIVE ACTION
1. Check liquid level
switch float for
position, float should
float up as the heater
fills with water. Check
switch by pivoting float
up and down to see if
solenoid clicks and
light goes on and off,
if not replace switch.
2. If solenoid does click
and the heater still
overflows, it could be
stuck in open position,
- remove and clean or
replace.
Excessive wood
usage
1. Defective liquid
level switch
2. Solenoid valve
stuck or corroded
Excessive
wood usage
Or
Overheating
(boiling)
Summary of Contents for LC2500