22
HARGASSNER Heating technology for
Biomass
A 4952 Weng OÖ Tel.: +43/7723/5274-0 Fax: +43/7723/5274-5 office@hargassner.at
III
6.4
Info Boiler
Info page about the HWT status
• HWT-loading
• Setpoint temp.
• Actual temperature
• HWT fill level display
• Pump status
If more HWT are parametrised, more info pages are also available. The symbol
besides the HWT pump shows if the pump is running or not (green=on, white=off)
Use the HWT icon to access the HWT setting options in the configuration
pages
• Button
One-time charge
Press the button to recharge the HWT once to its set temperature
6.5
Differential control information
Info page about the current status of differential control
• Differential control operating hours
• Total / day
• Current heat source temperature
• Current temperature at differential sensor (S2)
HARGASSNER
-
+
Mo,25.11.18 08:19
Heating circuit 1
LOWERING
Flow-target
Flow-Is 42°C
Pump
Mixer
FR40
Room temp.
Average outside temperature 3°C
ON
30°C
42°C
ON
Off
0.0°C
1
2
3
4
5
6
7
8
Pos. Description
Function
1
Heat circuit configuration
The button next to the corresponding heat circuit is used to jump to the setting options in
the configuration pages
2
Heating mode configuration
The button is used to enter the pop-up menu for selecting the heating mode
3
Heat circuit Off
The heat circuit is switched off (except for the frost protection function)
4
Heat circuit Automatic
The heat circuit runs according to the timer programme's settings.
5
Heat circuit continuous setback The room temperature is continuously being heated to the preset room temperature
(reduction/setback mode)
6
Heat circuit continuous heating The room temperature is continuously being heated to the preset room temperature
(heating mode)
7
Party mode
The heat circuit heats the room temperature to the set value (heating mode) and switches
back to the automatic timer programme during the next heating cycle (or after 24 hours at
the latest)
8
Reduction/setback mode
The heat circuit is reduced to the pre-set room target temperature (reduction/setback
mode) and
returns to the automatic timer programme during the next heating cycle
(or after 24 hours at the latest)
HARGASSNER
Mo,25.11.18 08:19
HWT 1
HWT-loading
HWT target
HWT Is
Pump
Release circulation pump
Circulation pump
Off
0°C
57°C
Off
NO
Off
45°C
HARGASSNER
45°C
55°C
Mo,25.11.18 08:19
Total hours
Day counter
6.9h
6.1h
Summary of Contents for Classic 12