III
HARGASSNER Heating technology for
Biomass
A 4952 Weng OÖ Tel.: +43/7723/5274-0 Fax: +43/7723/5274-5 office@hargassner.at
25
7
Manual operation
Manual operation
is used to:
• check all electrical functions
• check equipment after an error manually
To activate the function, press or press and hold the button.
To deactivate the function, press again or release the button
To activate continuous operation (max. 2 minutes), double-click the button
when the service settings are activated.
Only the selected function is activated. All other functions are inactive.
No. 1 Function check on the sliding grate
• Pressing the button opens and closes the sliding grate once.
Generated ash drops down into the ash box.
Press the button after each time the boiler is cleaned.
No. 2 Function check on the sliding grate
• Pressing the button either opens or closes the sliding grate once.
No. 3 Function check on the cleaning device
The grate opens completely and the cleaning motor starts running.
Press the button again to end the function check. The cleaning motor will
move to its final position and the grate will close.
No. 4 Function and rotation check of ash extraction motor
• Manual Forward or Backward of the motor
Press Backward button only
briefly
No. 5 Function and rotation check of stoker auger motor
• Manual Forward and Backward to fill the stoker auger
Press Backward button only
briefly
The stoker auger is only available without sliding grate when the service set
-
tings are activated.
No. 6 Functional test of vacuum turbine
No. 6a Function check on the changeover unit
W A R N I N G
Risk of injury due to unexpected operating statuses
• During manual mode no monitoring of limit switches or motors is performed.
Reverse operation of augers max. 2 [Sec.]
• Manual mode is only allowed to be executed by trained staff
Manual
Function
HARGASSNER
Mo,25.11.18 08:19
Open/Close
No.1 Manual 0.0 A
Sliding grate 1x open/close
HARGASSNER
Mo,25.11.18 08:19
Open
No.2 Manual 0.0 A
Sliding grate
Closed
HARGASSNER
Mo,25.11.18 08:19
On
No.3 Manual 0.0 A
Cleaning device
HARGASSNER
Mo,25.11.18 08:19
Forward
No. 4 Manual 0 mA
Ash removal
Backward
HARGASSNER
Mo,25.11.18 08:19
Forward
No. 5 Manual 0 mA
Stoker auger
Backward
ES without SR
HARGASSNER
Mo,25.11.18 08:19
On
No. 6 Manual
Suction turbine
Filling level: full
HARGASSNER
Mo,25.11.18 08:19
Pos.1
No. 6a Manual
Changeover unit
Pos.2
Summary of Contents for Classic 12
Page 64: ......