Optional remote controls
Using a remote control makes it easy to adjust the room temperature and also the
heating and reduction settings. The heating temperatures and times can be set
and changed with the FR35 and FR40 digital remote controls. One heat circuit
may be parametrised per remote control, which can be parametrised with or
without a room temperature sensor.
• 1 heat circuit or extension control board (
HC A
digital remote controls only)
• 2 heat circuits per extension module (
HKM
0 - 2
)
• 2 heat circuits per heat circuit controller (
HKR
0 - 15)
11.1 Digital remote control FR40
With the FR40, all the heat circuit functions available on the boiler can be set from
wherever the remote control is in the user's living space.
Operation modes:
Off
The heat circuit is switched off (except for frost protection).
AUTOMATIC
The heat circuit is operated according to set times.
REDUCTION
(in automatic mode)
The heat circuit is in permanent reduced mode.
HEATING
(in automatic mode)
The heat circuit is in permanent heating mode.
PARTY
(heating on a single occasion)
The heat circuit switches to permanent heating mode on a single occasion
and automatically reverts to automatic mode at the next preset heating time.
REDUCTION
(reduction on a single occasion)
The heat circuit switches to permanent reduced mode on a single occasion
and automatically reverts to automatic mode at the next preset heating time.
Fine adjustment of room temperature:
+
: Increase of up to 3 °C
-
Decrease of up to 3 °C
OFF