III
HARGASSNER Heating technology for
Biomass
A 4952 Weng OÖ Tel.: +43/7723/5274-0 Fax: +43/7723/5274-5 office@hargassner.at
31
9
Customer settings
In the standard menu, press the
Setup
button and then press the
Customer
button.
Select your desired setting value with the arrow button.
Select the values by touching the fields highlighted in white
The font colour of the parameters changes to
red
Press the
+
and
-
buttons to set the desired values - the display flashes.
Press and hold the
+
and
-
buttons to adjust the values quickly.
Confirm the set value with the green checkmark
9.1
HWT control
The day clock is set to weekly clock and the number of blocks is changed in
the installer settings (parameter D9 + D10)
9.1.1 Day clock
No. 1 HWT 1 day clock Mon-Sun
Setting the loading times of the boiler using the day clock
9.1.2 Week clock
No. 1a HWT 1 week clock
Setting the loading times of the boiler using the weekly clock
Selected day = green
9.1.3 Setpoint temperature
No. 2 HWT 1 - Setting the HWT set temperature
HWT loading is done only during the set
loading times
9.1.4 Circulation pump
No. 2a HWT 1 circulation pump
Setting the switching times of the circulation pump (if available)
HWT temperatures as per factory setting
HARGASSNER
Mo,25.11.18 08:19
ON
No. 1 HWT 1 day clock Mon-Sun
17:00
20:00
--:--
--:--
ON
Off
Off
HARGASSNER
Mo,25.11.18 08:19
No. 1a HWT 1 week clock
17:00
20:00
--:--
--:--
M
Tu W
Th
F
Sa Su
ON
ON
Off
Off
HARGASSNER
Mo,25.11.18 08:19
No. 2 HWT 1
Setpoint temp.
Default: 60 °C
60 °C
HARGASSNER
Mo,25.11.18 08:19
No. 2a HWT 1 circulation pump
ON
Off
ON
Off
ON
Off
0 °C
40 °C
20 °C
60 °C
00:00
24:00
12:00
15:00
21:00
18:00
06:00
09:00
03:00
HWT-loading starts as soon as the HWT temperature drops below 40 / 54 °C
40 °C
40 °C
54 °C
Summary of Contents for Classic 12
Page 64: ......