background image

Summary of Contents for HD-192B

Page 1: ......

Page 2: ... Working principle a Working principle b Dehumidifying cycle c Defrosting cycle d Safety function 2 3 Technical parameters 2 4 Dehumidification capacity chart 3 Installation 3 1 Delivery and storage 3 2 Installation environment 3 3 Power sources 3 4 Installation 4 Operation 5 Maintenance 6 Troubles and Countermeasures Appendix Dimension Drawing Parts Drawing and List 1 1 2 2 4 4 5 5 6 7 7 8 8 8 9 ...

Page 3: ... can controls the humidity accurately User can select as the requirement to the relative humidity by which the power consumption is minimised Besides it can defrost automatically thus can be used normally in low temperature environment and can be operated easily Suitable environment temperature 5o C a 42o C relative humidity 90 1 2 Warranty The warranty period is 12 months from the date of equipme...

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ...MH 1 500 2 500 4 500 Power source V 1Ph 220V 50Hz 3Ph 380V 50Hz Nominal rated power kW 1 6 4 12 8 5 Rated current A 7 5 7 6 15 4 Noise level dB A 57 59 65 Overall dimensions mm 600 x 365 x 973 777 x 480 x 1632 1232 x 460 x 1732 W x D x H Weight Kg 60 150 235 Note Nominal working condition 30 0o C 70 Notice Please use this unit under the specified environment and temperature condition strictly The ...

Page 8: ......

Page 9: ...ensure that no damage has occurred during trans portation and storage Any visible damage must be reported to nearest Harison representative 3 2 Installation Environment 1 The unit should be installed stably There should be one meter of space in front of the inflow and outflow There should be no large obstacle around it 2 The machine should be set far from heat source and inflammable gas 3 The cond...

Page 10: ... gives off di 2 Press ON OFF the running indicator lights on and the humidity display window lights on to display the previous set humidity The initial humidity setting is 60 and 3 seconds later the humidity display window light on to display current humidity Indicator Opertion RH display Memory Sctting Humidity Up Sct Humidity Down Defrost Memory Main ON OFF button HARISON INDUSTRIAL DEHUMIDIFIER...

Page 11: ...ow displays the humidity from 30 to 90 6 Keep unplug if do not use the unit for long time 7 Power supplies for HD 192B HD504B have phase and phase protecting function when out of connecting 3 phases are not connected rightly with machine s enactment all the buttons on control panel are dead moisture window shows E5 please exchange the phase or check power then operate the unit again 8 When switch ...

Page 12: ......

Reviews: