11
Save These Instructions 3-90-798 Dry Seasoned Wood Only!
Oakleaf Woodburning stove
B
A
B
A
B
A
CLEARANCE TO COMBusTIBLEs:
Corner Installation, vertical vent
CLEARANCE TO COMBusTIBLEs: Corner Installation
vertical vent, Horizontal Exit
A
shield Corner to Wall
14" / 356 mm
B
vent Pipe to Wall
21.75" / 552 mm
A
shield Corner to Wall
14" / 356 mm
B
vent Pipe to Wall
21.75" / 552 mm
Location
Location
CLEARANCE TO COMBusTIBLEs: Horizontal venting Configuration
Location
A
unit to side Wall
17" / 432 mm
B
unit to Back Wall
13" / 330 mm
C
vent Pipe to side Wall 26.5" / 673 mm
Corner Installation
d
shield Corner to Wall
14" / 356 mm
E
NfPA 211 specifies clearance of 18" / 457 mm (Although vent clear-
ance may be reduced using double-wall pipe, d must be followed)
B
A
C
E
d
*for clearance reduction methods, refer to NfPA 211 or Local Codes
NOTICE: When using rear flue configuration, a new upper rear heat shield, #1-00-797070
must be installed in place of the existing shield.
Pipe clearance may be reduced using double wall
or insulated connector pipe, provided that you
adhere to the specified clearances from the stove
itself. follow pipe manufacturer's guidelines.