10
2' Max
Chimney should be 2 feet higher
than anything 10 feet around it.
Chimney should be 2 feet higher
than anything 10 feet around it.
2" Minimum
Installing to a Prefabricated Chimney
When venting your 44 Magnum using a prefabri-
cated chimney, be sure to contact your local building
code authorities, and to follow the manufacturer's in-
structions exactly. Use a 5 or 6 inch manufactured type
HT chimney with a rating of 1000 degrees fahrenheit or
more.
Use only the manufacturer's parts; do not use
makeshift installation techniques. All prefabricated chim-
neys must be tested to either the U.S. or Canadian high
temperature standards, UL 103 or ULC-629.
Minimum clearances are set by the chimney manu-
facturer. Be sure to use the minimum clearance to
combustables that are set by the chimney manufacturer.
Installation with External Prefabricated Chimney
Installation with Internal Prefabricated Chimney
Fig. 13
Fig. 14