LISTED COAL BURNING ROOM HEATER
MODEL: "44 MAG"
GL-
SIDEWALL-BACKWALL
INSTALLATION
WITH SIDE SHIELDS
I N S T A L L W I T H M I N I M U M
CLEARANCES TO WALLS AS
S H O W N
TESTED TO :
UL 1482
ASTM E1509-95
ULC-S627
TEST DATE: JUNE 9, 1998
MINIMUM CLEARANCES TO COMBUSTIBLES:
SIDEWALL TO STOVE
16"
8"
BACKWALL TO STOVE
11"
11"
CEILING TO STOVE TOP
20"
20"
STOVE CORNER TO DIAGONAL WALL
10.5"
10.5"
CHIMNEY CONNECTOR TO WALL
5"
5"
PREVENT HOUSE FIRES, OPERATE WITH VIEWING & ASH DOOR CLOSED.
UNIT MUST BE PLACE ON A NON-COMBUSTIBLE FLOOR PROTECTOR EX-
TENDING 6" TO THE FRONT, 6" TO SIDES AND 1" TO REAR.
EXHAUST TYPE: CLASS "A" CHIMNEY AND CLASS "A" CHIMNEY CONNEC-
TOR. CHIMNEY MUST PROVIDE DRAFT OF AT LEAST .03" W.C.
ELECTRICAL RATING: 3 AMPS, 120 VOLTS, 60 HERTZ
FUEL: ANTHRACITE RICE COAL. ALSO BITUMINOUS OF SAME SIZE.
INSTALL AND USE ONLY IN ACCORDANCE WITH MANUFACTURER'S INSTAL-
LATION AND OPERATING INSTRUCTIONS. CONTACT LOCAL BUILDING OR
FIRE OFFICIALS ABOUT RESTRICTIONS & INSTALLATION INSPECTION IN
YOUR AREA.
U.S. ENVIRONMENTAL PROTECTION AGENCY THIS UNIT IS ONLY FOR
BURNING COAL. USE OF ANY OTHER SOLID FUEL EXCEPT FOR COAL IGNI-
TION PURPOSES IS A VIOLATION OF FEDERAL LAW.
INPUT RATING: .55 TO 3.75 LBS PER HOUR.
DO NOT CONNECT THIS UNIT TO A CHIMNEY SERV-
ING ANOTHER APPLIANCE
MANUFACTURED BY:
HARMAN STOVE COMPANY
352 MTN. HOUSE ROAD
HALIFAX, PA. 17032
DO NOT REMOVE THIS
LABEL
SIDEWALL-BACKWALL
INSTALLATION
WITHOUT SIDE SHIELDS
16"
CORNER INSTALLATION
WITH OR WITHOUT
SIDE SHIELDS
6"
6"
6"
FLOOR
PROTECTOR
MINIMUM SIZE
1"
WITH SIDE
SHIELDS
WITHOUT SIDE
SHIELDS
10.5"
5"
5"
11"
11"
5"
8"
G U A R D I A N
Summary of Contents for 44 Magnum