15
#5 Installing into an existing
fireplace
chimney
This method provides excellent venting for nor-
mal operation. This method also provides natural
draft in the event of a power failure.
In Canada and some places in the US it is
required that the vent pipe extend all the way to the
top of the chimney.
In this method a cap should also be installed
on the chimney to keep out rain. Be sure to use
approved pellet vent pipe fittings. Seal pipe joints
with silicone in addition to the sealing system used
by the manufacturer. Pipe size should be increased
to 4" using this method.
#6 Installing into an existing
chimney
This method provides excellent venting for nor-
mal operation. This method also provides natural
draft in the event of a power failure.
In Canada and some places in the US it is re
-
quired that the vent pipe extend all the way to the top
of the chimney. The pipe or liner inside the chimney
should be 4" diameter.
In this method a cap should also be installed
on the chimney to keep out rain.
Fig.24
Fig.25
venting