1 1
Basement Installation
To install a DVC 500 in a basement you will
need additional DVC vent sections. These sections
are made with a 316 stainless steel liner and a 20
gauge galvaneeled outer shell. Each joint is sealed
with a gasket and is bolted together with 4 bolts.
In order to maintain the best seal, there are no
adjustable sections. There are straight, 45 degree,
and Tee fittings. Refer to Page 13 for all the
sections available.
Never use venting other than Harman
DVC venting inside the building. It is the
only vent certified for this application.
Refer to page 11 to calculate which section
will be needed for your installation.
Corner Installation
A corner installation requires a 45 degree
section in addition to the standard wall termina-
tion.
In order to cut a hole in the wall that will
allow the stove to be placed an equal distance to
each wall, refer to Page 12.
Wall Termination
Tee with cover plate
Straight sections
Joint covers
Tee with cover plate
Installation
fig. 10
fig. 11