Exception F200 Wood Insert
4
Operation
FOR USE IN THE U.S. AND CANADA
The door must be closed while the insert is in nor-
mal operation, and the gaskets routinely examined for wear
and replaced when necessary. Good door seals are
important for maintaining control of the insert. Operating
the insert with the door inadequately sealed, could create
a serious over firing condition (discussed later in this sec-
tion).
The glass used in your Exception is manufactured
to exact standards to withstand the high heat of the fire,
but like all glass, it must be treated with common sense
and care. Never abuse the glass by slamming the door
shut or striking the glass with a heavy object. If the glass
is broken or damaged, do not operate the insert until it has
been replaced (See instructions in the Maintenance sec-
tion.)
Operating As A Fireplace
To operate as a fireplace, open the damper and keep
it open. Next, open the door and place the optional screen
(part number 3-40-727336) over the door opening. Check
for smoke spillage into the room. If smoke is escaping
into the room, remove the screen and close the door. Al-
ways wear gloves when placing or removing the screen.
Never leave the unit unattended with the door open.
Andirons
The andirons keep the fuel from coming in direct
contact with the glass, and keep hot coals and embers
from spilling out while reloading. Never build a fire di-
rectly against the glass.
Do not use a grate or elevate the fire. Build wood
fire directly on insert hearth.
The Insert
Doors
Your insert has a large glass-paneled door for
loading and fire viewing. To open the glass door, turn
the handles clockwise and pull out; to close the door,
return the handles to an open 9 o'clock closed 6 o'clock,
and push in to engage the latch while turning the
handles counterclockwise.
If the latch on your Exception door needs adjust-
ment, follow the instructions given in the Maintenance
section of this manual.
General Considerations
Draft
Before you install and operate your Exception
wood insert, please read the entire contents of this manual.
Pay particular attention to the explanation of draft and its
ef fect
o n
in sert
p er fo rm an ce
in
the Installation section. By following the installation and
operating guidelines, you will ensure proper draft and gain
maximum efficiency and enjoyment from your insert.
Fuel
Your Exception burns wood very efficiently. Here
are some guidelines concerning log size and moisture con-
tent that will help you obtain the best performance.
Select hardwoods if possible, as they are heavier
and contain more heating capacity (BTU’s) per load than
do softwoods. Wood should be split and stored under
cover for “seasoning” - a year is recommended. Your
insert is not an incinerator - do not burn garbage, painted
or treated wood, plastic, or other debris.
Keep the area around the insert free from clut-
ter. Keep all combustibles, including fuel, beyond the code-
required clearance distance (48" or 1215 mm in the U.S.,
1525 mm or 60" in Canada). Never store fuel in front of
the insert where it could interfere with door operation,
safe loading, and ash removal.
Do not burn garbage or flammable fluids
such as gasoline, naptha, or engine oil.